H820 User Manual 
Step 2) set the dedicated phone number for SMS Alarm
Step 3) Configure the voice command
normal signal count for check again: to prevent repeating alarm.
With the setting above, the H820 router checks signal every 20s, if all of 10 times with signal 0
quality, H820 Router will send Alarm via SMS. After the alarm, this feature will be locked, but H820
Router keeps checking signal quality every 20s, if continuous 8 times are with signal quality better
than 0, the alarm feature will be unlocked, then the alarm feature starts work again.
3.3.10 Link Backup (Route Redundancy)