H685 User Manual
E‐LinsTechnologyCo.,Limited
Te
l
:
+86‐(755)33231620E‐mail:sales@e‐lins.com[email protected]omwww.szelins.comThisfunctionwilldetectthestatusof3Gbypingandcompletethecorres ponding
actionsaccordingtothepingresult。
z Checkthebox,startthenetdetectionrestartfunction.
z Detectionmethod(PING):fill theserverdomain name orIP, and thenclickthe
detectionbutton,anddetectifthefill‐inisright.
z Detection interval time (second):the interval time between the first detection
andtheseconddetectionis60‐86400seconds.
z Detection counter: ifyou can’t get therightresult by pingwhenthe detection
frequencyisthesameasthefill‐intimes,thedevicewillrestart.
z Restart the counter before the detection function get into dormant state &
detection function dormant time: this will pr otect the device against the
damage caused by the continuous restarts, which are caused by the ping
failurebytheresultofthefaultinfillingtheserverdomainname.Afterseveral
times of restarts, the device will get into the dormant state. After that the
detection will continue, and now the counter in flash will become zero and
recount.
Note:Thisfunctionwillbeonlyvalidonlyin3Gpermanenton‐lineand
dialingaccordingtothesettingtime,otherstatesnot.Insetting,firstlyyou
mustdetectifthefilled‐inserverdomainnameorIPisvalid.
3.3.14.3 UpgradeFirmware
Upgradethefirmwaretoobtainnewfunctionality.Ittakesabout2minutes.
3.3.14.4 ParameterManagement
Hereyou can make a backup of current settings or restore previous settings of