E-Lins D120 Series DTU Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 19
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
D120 DTU Modem Quick Start
E-Lins Technology Co.,Limited
Add:Bld22, Longxi Garden, Nonglin Road, Futian, Shenzhen, 518000, China
Tel: +86-755-83700465 E-mail: [email protected] www.szelins.com
……
……
+++ //exit SerialNet mode
AT+iTUP=0 //disable the trigger up function
AT+iPARS //parameters save
Note: our test server: 218.108.22.22: 80 it will send 1 “ok” to client per minute
Socket mode
AT+iSTCP:ip,port //establish a tcp connection to the IP and port
I/(000) //000 is the Right connection handle
I/ERROR(075) //not logon cellular networkplease checking Card and Signal quality
I/ERROR(207) //logon cellular networkBut can’t connecting to TCP server programmeyou should
to check firewall, IP Port and port listen if collide with them
AT+iSSND%:000, n:*******
//send a stream(******) to connect 000, length is (n),
AT+iSRCV: 000 //receive data from connection 000
AT+iSCLS: 000 //close the connection 000
Note: our test server: 218.108.22.22: 80 it will send 1 “ok” to client per minute
UDP Connect
SerialNet Mode
AT+iSTYP=1 //set UDP mode
AT+iHSRV=ip:port //set opposite IP and port
AT+iLPRT=port //set local port for listen
AT+iTUP=2 //always online
AT+iPARS //parameters save
AT+i!SNMD //switch to SerialNET mode (please must input this command after parameter save,
then the DTU modem will be into communication mode for work)
……
……
…… //communication
……
……
+++ //exit SerialNet mode
AT+iTUP=0 //disable always online function
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19

Comentários a estes Manuais